I just got my SPA3102 ATA delivered but unable to connect to the web
interface to connect. I have connected it to one of the ports on my Netgear router and although I can ping it I cannot access the web interface to configure? Secondly I notice that the Power light kees flashing constantly when one end of the network cable is inserted into the Ethernet Port and the other into one of the router ports? The power led only works when an ethernet cable is connected into the Internet port. What am I doing wrong or is the ATA faulty? |
|
|||
|
Charles wrote on 04/02/2007 :[color=blue]
> I just got my SPA3102 ATA delivered but unable to connect to the web > interface to connect. I have connected it to one of the ports on my Netgear > router and although I can ping it I cannot access the web interface to > configure? > > Secondly I notice that the Power light kees flashing constantly when one end > of the network cable is inserted into the Ethernet Port and the other into > one of the router ports? The power led only works when an ethernet cable is > connected into the Internet port. What am I doing wrong or is the ATA faulty?[/color] Try connecting a PC directly to the LAN port of the SPA3102 - it does have an integral router, after all. Disable the router part & give the SPA a static IP address which matches your regular router's network.... |
|
|||
|
Charles wrote:[color=blue]
> I just got my SPA3102 ATA delivered but unable to connect to the web > interface to connect. I have connected it to one of the ports on my Netgear > router and although I can ping it I cannot access the web interface to > configure? >[/color] By default, you will not be able to access the webinterface from the WAN (internet) side of the device. Tim |
|
|||
|
On Sun, 04 Feb 2007 21:56:50 GMT, Jono <nothanks@blueyonder.invalid>
wrote: [color=blue] >Charles wrote on 04/02/2007 :[color=green] >> I just got my SPA3102 ATA delivered but unable to connect to the web >> interface to connect. I have connected it to one of the ports on my Netgear >> router and although I can ping it I cannot access the web interface to >> configure? >> >> Secondly I notice that the Power light kees flashing constantly when one end >> of the network cable is inserted into the Ethernet Port and the other into >> one of the router ports? The power led only works when an ethernet cable is >> connected into the Internet port. What am I doing wrong or is the ATA faulty?[/color] > >Try connecting a PC directly to the LAN port of the SPA3102 - it does >have an integral router, after all. Disable the router part & give the >SPA a static IP address which matches your regular router's network....[/color] To expand on that... I am looking at this as though the SPA-3102 set up tabs are similar to the SPA-3000. On the System tab make the 'Gateway' and the 'Primary DNS' equal to the IP of your router. Set DHCP to 'no'. Assign an IP of your choice, which falls into the allowed IP range programmed into your router, to the Static IP for your ATA. For example: You might have a router with an IP of 192.168.1.1 so set the Gateway and Primary DNS to that and use, say, 192.168.1.5 as the 'Static IP' for your SPA-3102. Once that is done you would then call up 192.168.1.5 in your browser. Remove 'no_spam_' from email address. |
|
|||
|
Brian A has brought this to us :[color=blue]
> On Sun, 04 Feb 2007 21:56:50 GMT, Jono <nothanks@blueyonder.invalid> > wrote: >[color=green] >> Charles wrote on 04/02/2007 :[color=darkred] >>> I just got my SPA3102 ATA delivered but unable to connect to the web >>> interface to connect. I have connected it to one of the ports on my Netgear >>> router and although I can ping it I cannot access the web interface to >>> configure? >>> >>> Secondly I notice that the Power light kees flashing constantly when one >>> end of the network cable is inserted into the Ethernet Port and the other >>> into one of the router ports? The power led only works when an ethernet >>> cable is connected into the Internet port. What am I doing wrong or is the >>> ATA faulty?[/color] >> >> Try connecting a PC directly to the LAN port of the SPA3102 - it does >> have an integral router, after all. Disable the router part & give the >> SPA a static IP address which matches your regular router's network....[/color] > To expand on that... I am looking at this as though the SPA-3102 set > up tabs are similar to the SPA-3000. On the System tab make the > 'Gateway' and the 'Primary DNS' equal to the IP of your router. Set > DHCP to 'no'. Assign an IP of your choice, which falls into the > allowed IP range programmed into your router, to the Static IP for > your ATA. For example: You might have a router with an IP of > 192.168.1.1 so set the Gateway and Primary DNS to that and use, say, > 192.168.1.5 as the 'Static IP' for your SPA-3102. > Once that is done you would then call up 192.168.1.5 in your browser.[/color] Once logged in, it's likely to be similar to the SPA2100 - the basic interface will yield two fields, "Voice" & "Router" |
|
|||
|
Thanks for all the good suggestion. I forgot to mention that my PC's are
connected to a Netgear WPN824 router and would like to connect the the SPA3102 directly to one of the ports as my PC's are networked. <nothanks@blueyonder.invalid> wrote in message news:mn.25247d72f7b7c1e2.48968@blueyonder.invalid...[color=blue] > Charles wrote on 04/02/2007 :[color=green] >> I just got my SPA3102 ATA delivered but unable to connect to the web >> interface to connect. I have connected it to one of the ports on my >> Netgear router and although I can ping it I cannot access the web >> interface to configure? >> >> Secondly I notice that the Power light kees flashing constantly when one >> end of the network cable is inserted into the Ethernet Port and the other >> into one of the router ports? The power led only works when an ethernet >> cable is connected into the Internet port. What am I doing wrong or is >> the ATA faulty?[/color] > > Try connecting a PC directly to the LAN port of the SPA3102 - it does have > an integral router, after all. Disable the router part & give the SPA a > static IP address which matches your regular router's network.... > >[/color] |
|
|||
|
Charles submitted this idea :
[color=blue] > > <nothanks@blueyonder.invalid> wrote in message > news:mn.25247d72f7b7c1e2.48968@blueyonder.invalid...[color=green] >> Charles wrote on 04/02/2007 :[color=darkred] >>> I just got my SPA3102 ATA delivered but unable to connect to the web >>> interface to connect. I have connected it to one of the ports on my >>> Netgear router and although I can ping it I cannot access the web >>> interface to configure? >>> >>> Secondly I notice that the Power light kees flashing constantly when one >>> end of the network cable is inserted into the Ethernet Port and the other >>> into one of the router ports? The power led only works when an ethernet >>> cable is connected into the Internet port. What am I doing wrong or is the >>> ATA faulty?[/color] >> >> Try connecting a PC directly to the LAN port of the SPA3102 - it does have >> an integral router, after all. Disable the router part & give the SPA a >> static IP address which matches your regular router's network.... >> >>[/color] > Thanks for all the good suggestion. I forgot to mention that my PC's are > connected to a Netgear WPN824 router and would like to connect the the > SPA3102 directly to one of the ports as my PC's are networked.[/color] That's not a problem, once you have configured it correctly. Indeed, I have an SPA2100 connected in the same way as you intend. |
![]() |